Features and Specifications

      Power Output                  :   3.5KW   
      Frequency                       :   40KHz  
      X-Ray Tube                     :   Fixed anode 
      focus                               :   1.5  
      Tube Voltage                   :   40110KV (interval 1KV)  
      Tube Current                   :   4049KV 63mA 1125 mAs 
                                                   5059KV 55mA 1110 mAs 
                                                   6069KV 45mA 190 mAs 
                                                   7079KV 40mA 180 mAs 
                                                    8089KV 36mA 171 mAs 
                                                    9099KV 32mA 163 mAs 
                                                    100110KV 20mA 140 mAs  
       mAs                                :   1.0125 mAs 43 steps  
       Power Supply                 :   220V±10℅ 50Hz  inner-resistance≤1.0Ω  
      Operation Method           :  Wire/Wireless control  

I.Parameters 

General-purpose, mobile  X-ray system, dedicated for radiography of standing, seated or recumbent patients as well as for patients in bed or on the operating table and as a standby emergency unit. High-frequency X-ray generator with the following output:

1. Generator output: 3.5 kW

2. kV range:  40 kV - 110 kV in 1kv steps 

3. mA range:    20~6mA

4. Exposure time: 4 films per min, less than 20 ms per film

5. X-ray tube:

Stationary anode tube with a focal spot of 1.5*1.5 mm 

6. Collimator:

bright field light beam collimator with 120 W halogen lamp and auto shut-off facility.

7.Power requirements :Single phase 220 V +/- 10% Voltage tolerance; 50 Hz power supply 

8.Mobile stand: Light-weight, low height mobile and easily maneuverable stand. 

9.The mobile radiographic unit also include a handheld control and a microwave wireless remote control for the 20-meter microwave remote Without the restriction of Barriers and directional ,different from the infrared remote control . Grids reduce the fog line filters and raise the degree of scattering contrast.

10.The unit is provided with a line (power) cord of acceptable durability, quality, length and is secured with adequate strain reliefs 

The unit include, power plugs that are sufficient for the maximum voltage and current of the unit. 

II Standard Configurationts

1) modular/high frequency /high voltage X-ray generator& Inverterd power supply        1 set

2) mobile stander                                                            1 set

3) mobile operating system                                                    1 set

4) adjustable collimator                                                       1 set

5) remote control unit                                                        1 set

6) common attachments                                                    Certain

7) Options : PLX152 Table for Mobile X ray Equipment and Upright Bucky Stand 

 The size of PLX152 is 2000mm×700mm×500mm, cassette movement range is 1680mm . Low bed to facilitate the patient up and down, Longitudinal center of the bed frame with the cassette center line are consistent. To make the center of symmetry when photograph,and the movement range of cassette get larger And have manual brakes convenient location, bed body can 360 ° moving flexible 

IIIFunction

      The machine is mobile modular X-ray photography of medical diagnostic equipment for wards, emergency rooms, operating rooms, ICU, etc. on the head, limbs, chest, waist , abdomen and many other parts.

IV.Features

1)With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of pictures.

2)With techniques of KV analog closed loop control, mAs digital closed loop control and micro-processing real-time control to ensure precision and repeatability of the dose.

3)With kV, mAs two button adjustment, LCD display, multifunction of safety guard.

4)With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.

5)With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator.

6)With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph.

Product Name:
High Frequency Mobile x ray Machine  
Item No: TDM8101A