TDM8220 is used in Department of Radiology, Medical center for disease control centers,other health institution etc. This machine is suitable for human esophagus, chest and stomach, abdomen, limbs and other parts of continuous perspective diagnostic work
Ⅱ Standard Configuration:
1 Host system
1)console one set
2)Column device
3)Examine table
2 9 " Toshiba brand image intensifier one set
3 High frequency high voltage X-ray generator and high frequency inverter one set
4 TV Equipment one set
1) Ultra-low-light digital video camera
2) High definition monitor
3)Digital controller (the control)
5 Collimator( Straight line with rotary and Electric circular iris collimtor ) one set
6 Optional equipped with a removable, oscillating grid ,grid ratio 10:1
ⅢSystem performance and parameters of TDM8220 High Frequency Remote-Control Fluoroscopic Equipment
Category
|
Item
|
Content
|
Fluoroscopy Capacity
|
Perspective max rated capacity
|
Tube current 8 mA ,Tube voltage 120 kv
|
automatic fluoroscopy
|
Tube voltage: 40kV~120kV ,adjust automatically
Tube current :0.3mA~4mA .adjust automatically
|
Manual Fluoroscopy
|
Tube voltage 40 kv,110kv, continuous
Tube current :0.3mA~~4mA continuous
|
pulse frequence
|
Tube voltage 40kV~120kV, continuous
Tube current : 4.1mA~8mA continuous
|
X ray tube
|
X ray tube special for High frequency
|
Dual focus fixed anode x-ray tube: large focus:1.5, small focus: 0.3; High Frequency Power Supply , Main inverter frequency :60KHZ, thermal capacity :34KJ(47Khu)
|
Video System
|
Image intensifier
|
Toshiba 9 "Image Intensifier (230mm)
|
Video camera
|
Ultra-low-light digital camera for medical A / D digits 12bit
|
Monitor
|
Centre resolution greater than 1000 lines,field frequency 75Hz
|
Central control
|
High definition progressive scan output mode, multi-level noise reduction, multiple images stored; image vertical, horizontal image flip, positive and negative turn; LIH (last frame of the image to freeze)
|
Structure
|
Column
|
Vertical lifting range: ≥ 880mm focal screen distance: 1000mm
|
Examine table
|
Lateral movement range: ≥ 180mm;
chassis 360 ° electrical rotation
|
Performance
|
Feature
|
1、Using high-resolution image enhancement system, can reduce the dose, the doctor can clear room operation.
|
2、With electric up and down movements, electric lateral movement, power rotation, to really realize people do not move while the machine move, safety and reliability.
|
3、Ultimate resolution of the dynamic image 2.0LP/mm. Dynamic image without smearing.
|
4、With the fluoroscopy KV / MA automatic tracking feature, the image brightness, sharpness automatically at its best.
|
5、To achieve remote control of the operation, the maximum degree of protection from medical X-ray radiation effects, the patient doses significantly reduced.
|
6、Hand brake and foot brake are two control modes, flexible switching, easy application.
|
7、Programmable LCD with touch screen graphic, simple, elegant
|
8、Electric iris limited beam, which can be electric rotary, electric opening and closing, electric O-ring.
|
9、With the microphone to convenient doctor compartment operation.
|
Use
|
This machine is suitable for human esophagus, chest and stomach, abdomen, limbs and other parts of the work of continuous fluoroscopy diagnosis.
|
|
|
|