Features and Specifications

Function

gastrointestinal fluoroscopy/radiography, gastrointestinal examination, chest radiography, head and whole body bone radiography

  gastrography, Esophagography, Myelography, Arthrography, cholangiography, bronchography, venography, angiography, urography, hysterosalpingography, Pediatric Radiology, treat application of several intervention radiology

 feature

★ base the optimization principle to produce, excellent config of whole system, satisfy clinical personalized requirement

★ latest technology of high frequency mainframe, digital image collection, gain the high quality image easily

★ show human-machine interface directly, excellent operation system, make man-machine conversation more conveniently and easy to understand

multiple safety control, make the image quality and radiation dose to achieve organic balance

★ strong function of digital image processing, overall compatible with DICOM network application     

The unit is available for medical teaching, research, medical units for gastrointestinal X-ray spot film photography, remote control compartment, fluoroscopy and other Traumatic Radiography etc of X-ray routine examination, Can be used for  gastrointestinal imaging, cholangiography, Urinary tract imaging and Deep vein imaging and other imagings ; Can used for fluoroscopy of esophagus, breast, gastrointestine, Abdomen and limbs and spot film photography; Can do the operation of Fracture reduction and Taking foreign body from  in vivo .

Ⅱ Main Features : 

Diagnostic table 

1·Visual display of man-machine interface, touch screen control, makes man-machine conversation more intuitive, convenient and easy to understand.

·2Programmable controller technology, high control precision, good stability, excellent anti-jamming performance 

·3Inverter control technology, When the table move, it can soft start, soft stop, smooth no noise, more accurate positioning 

·4Reliable, high precision of angular displacement sensor technology, low dynamic noise, and long mechanical life.

·5High-resolution of rotary encoders, high accuracy of auto-slice, security and stability.

·6Rotation range of 90 ° ~ 0 ° ~ -25 °, can take routine examination of digestive organs , can also be used for a variety of special examination 

·7Humanized Design of diagnostic table lateral switch , near station positioning make the operation more convenient.

·8Toshiba's high-quality image intensifier, to further enhance image sharpness, contrast, more easily, to clearly identify Lesions.

·9Move a wide range of spot film device, apply the operation fo People do not move with the operation of motor way easily to complete taking from the throat, esophagus,To the lower abdomen of a series of examinations .

·10Spot film box open on their own, safe and reliable operation. 

2. Generator

1With X-ray Radiography and perspective function of generator, maximum output power of 50 kW.

2Output voltage of 150 kV.

3With a smaller, lighter, modular design.

4In the exposure process, kV and mA can be adjusted to achieve a constant radiation output.

5Large-screen LCD flat panel used to display the APR conventional conditions and practical projects.

6User-friendly system configuration.

7Operator can modify the APR technology items.

8Provide APR /-ray tube data downloads.

9A variety of automated diagnostic procedures, and operators with prompts 

.•10With serial RS232 communication interface

11Operation can be individually programmed for the APR, and APR and manual techniques for programming options

12Programmable settings, calibration, and conduct regular APR (by connecting an external computer).

13For ABS (Automatic Brightness Stabilization) circuit select four kinds of kV and mA curve.

Ⅲ Main Specifications 

Item

Content

Technical parameter

Power supply

Voltage

380V±38V

Frequency

50Hz±1Hz

Capacity

≥65kVA

internal resistor

≤0.17Ω

Digital X-ray high voltage system (import high-frequency generator ) 

Power Output

50KW

photography

Tube Voltage

40kv—150kv step regulation

Tube Current

10mA—630mA step regulation

Exposure time

1.0s—6300ms step regulation

Control interface

Touched LCD

fluoroscopy

Tube Voltage

40kv—125kv step:2kv continuous regulation

Tube Current

0.5mA—6mA continuous regulation

Automatic brightness for fluoroscopy IBS

Automatic brightness trackingmultiple settings beforehand 

Digital Controlled X-ray Tube

Toshiba, Japanese

Model

E7252

Tube FocusLarge Focus/Small Focus

1.2mm /0.6mm

Input Power

Large focus:75kW  small focus: 27kW

thermal capacity

210KJ

Rotary anode speed

2700rpm

Micro-computer control digital tube remote diagnostic table

Material of the tabletop

 high strengthlow absorb carbon fiber

Rotation of the table

90°~0°~-25°

Transverse travel of table

±110mm

Longitudinal travel of the photography holder and film spot device

≥720mm

X-ray Focus—film gauge

1100 mm—1500 mm

Rotating foot plate

±360° rotation

Full film photography size

8″×10″—14″×17″

Dividing method for spot film

Full film, half dividing, three parts dividing, four parts dividing

Control method for diagnostic table

Remotetable controlfrequency conversion soft starting and stopping

beam limiter         

Electric Multi-leaf

Voice interaction

Two-way microphone system

fixed bucky device for table

Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cmfixed type: 15″×18″

Digital Image TV System

Image Intensifier

TOSHIBA (9″) Image Intensifier 

high resolution CCD digital cameras

ultra-low-lightstandard 470000 pixelselecting 1 mega-pixel

Monitor

14medical high definition monitor, horizontal  central resolution ratio :1000 linesfringe: 800 linesvideo bandwidth: 12.5MHz50bitimage number/second: 25 frame

Digital Picture Processing System

CCU Sentinel

High definition line by line output mode, 8 level noise reductionstore 8 imageLIHfreeze the last framethe image can be turned vertically and horizontallypositive and negative image; OSDmonitor show

Product Name:
X ray digital system  
Item No: TDM8600